TRY PRODUCTION GRAPHITIZATION FURNACE
Application:
This continuous furnace can only be used for processing materials need small feed port shaped round or square or flat. Or to say all kinds of small volume carbon material’s graphitization treatment, such as high volume pitch based carbon fiber, VGCF, silicon carbide fibre, graphite paper and all these materials must can stand certain tension but can be pulled together by itself.
Features
● Max work temperature:3000℃, standard work temperature 2850℃
● Atmosphere condition:N2 or Ar2 gas
● Medium induction heating method, high power efficiency rate, high temperature rise speed, environment protection and energy saving, high safety standard, small floor area, easy operation and maintenance.
● Human computer interface for easy data input and operation process.
● PLC programmable automatically controlled instrument for furnace operation, temperature control, maintenance alarm and real-time recording.
● High precision red infrared thermometer guaranteed the accuracy of temperature measuring. Digital intelligence temperature control system can automatically and precisely complete the temperature measuring and control, it also can store 20 programs for about 400 sections heating curve formulas.
● Internal closed loop pure water cooling system; Fully anti-dust design with monitoring on water temperature and water positions.
● IGBT power devices with full protections and controls on overload, short circuit and over pressure problems.
● All the components are serial numbered according to the schematic, greatly decreased the maintenance time and made it possible for remote maintenance.
● Complete equipment configuration including:Vacuum system; Purification system; Water cooling system; Tail gas eliminate treatment system; DCS central control system
Specification:
typespec |
Cylindrical shape |
Square shape (W×H mm) | ||||
Dia of feed port | Φ50 | Φ100 | 200×40 | 500×80 | 700×80 | 900×80 |
Length of heating zone | 1000 | 1200 | 1000 | 2000 | 6000 | 8000 |
Max temperature | 2950 | 2950 | 2950 | 2900 | 2850 | 2850 |
Heating method |
Medium induction heating | High purity graphite heating | ||||
Length of air curtain | 200 | 400 | 500 | 800 | 1000 | 1200 |
Length of cooling water | 200 | 400 | 500 | 800 | 1000 | 1200 |
Dew-point of furnace | -70 | -70 | -70 | -70 | -70 | -70 |